Bradford Fireseal Rockwool Party Wall Sealers
Bradford Fireseal Party Wall Sealer is a non-combustible, plain (unfaced) stone wool blanket for a separating wall (party wall) between dwellings. It is packed, compressed, into the gap between the top of the wall and the underside of the roof covering, to help meet the fire resistance requirements between adjacent tenancies.
Where to use it
Bradford intends the sealer to meet the Deemed-to-Satisfy requirements for inter-tenancy walls in multi residential applications in Class 1 buildings only. Its design guide shows it:
- compressed between tiled or metal roofing and the top of a fire-rated separating wall
- filling the void between roof battens where they run over the wall
- over the foil of Anticon roofing blanket, after the blanket has been peeled back
The sealer is for the top of the wall and, depending on cavity width, vertical joints. For vertical joints, Bradford also makes Fireseal Party Wall Batts, which are not meant for sealing the top of a wall. Use the sealer only indoors, where it is protected from direct UV light, water and wind pressure during and after installation.
Bradford's product technical statement says the sealer meets the definition of 'mineral fibre' in the Deemed-to-Satisfy requirements for separating walls in the ABCB Housing Provisions Standard 2022 Amend. 2 and 2025, 9.3.1(3)(b) and 9.3.1(4)(b).
Fire performance
- Non-combustible when assessed to AS 1530.1, meeting NCC 2022 and NCC 2025 Volume 1 C2D10(1)
- Fire hazard properties (AS/NZS 1530.3): Ignitability 0, Spread of flame 0, Heat evolved 0, Smoke developed 0-1
- Fusion temperature: onset melting temperature above 1200°C (ASTM E 794)
- Density: 50kg/m³
- Not suitable for use in BAL-FZ
Installed as compressed packing in a separating wall, the sealer does not reach its stated R-value. Bradford says the compressed R-value must be calculated case by case.
Installation notes
- Isolate the power before installation.
- Cut the sealer to fit tightly into the prepared opening and install it with at least 10% compression.
- Install it as a single width across the entire party wall.
- Do not route penetrations through the sealer.
- Under a metal roof with Anticon roofing blanket, peel the blanket back so the sealer sits over the foil only.
- For roofs without sarking, the design guide details show the stone wool protected with a damp course.
The Installation tab lists the steps. AS 3999 gives further installation guidance.
Good to know
- Unfaced stone wool is not a water or vapour barrier.
- It is not suitable as an exposed internal wall or ceiling lining where a Group Number is required.
- Do not modify the product: compliance applies only to the product as listed in the product technical statement.
- Store packs in the original packaging in a cool, dry area, sealed when not in use, and not under direct sunlight for long periods.
- The fibre is listed by Safe Work Australia as man-made vitreous fibre (stone wool) of low bio persistence. Under EU ATP 31 (2009) these fibres are not classified as an irritant or as carcinogenic.
Request a quote
Bradford Fireseal Rockwool Party Wall Sealers
Thanks, your request is on its way.
We’ll get back to you with pricing within one business hour.
Step by step
Summarised from the Fireseal Party Wall Sealer Product Technical Statement PTS159 (Issue A, May 2026). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)
- Isolate power before installation.
- Cables surrounded by bulk insulation may overheat: wiring to AS/NZS 3000:2018 or later may be surrounded for up to 400mm, otherwise seek advice from a licensed electrician.
- When the sealer is used as compressed packing in a separating wall, install it with at least 10% compression.
- Install the sealer as a single width across the entire party wall.
- Do not route penetrations through the sealer.
- Where Anticon roofing blanket is installed under a metal roof, peel back the insulation blanket so the sealer sits over the foil only.
- Use the sealer only where it is protected from direct UV light, water and wind pressure during and after installation.
- Store packs in a cool, dry place in the original packaging, sealed and out of direct sunlight.
Additional installation guidance for this product can be found in AS 3999. Not suitable for use in BAL-FZ.
Insulation Installation - Do It Yourself
Many homeowners choose to install their own insulation. Done properly, it can be a rewarding DIY project that makes your home more comfortable and energy efficient. To get the best results, it’s important to install insulation batts correctly. Otherwise, gaps or compression can significantly reduce their performance. If you choose to take on the home insulation installation yourself, we strongly recommend that you familiarise yourself with the proper process. Make sure you check the relevant standards prior to commencing the installation.
Using a sharp knife, and a thin plank of wood as a guide, can make cutting insulation batts easier. Experienced insulation installers will often size up the cut with a glance and press the insulation against a vertical timber wall stud before cutting the batt to the desired width or length. This can save time, but care must be taken to ensure that you keep the knife blade well clear of any wiring or other appliances.
General install tips
DIY Install Tips for Beginners
The following principles of installing insulation will ensure the best possible performance from home insulation.
- Avoid gaps in insulation
- Do not compress bulk home insulation
- Allow clearance around appliances and fittings
- Protect your home insulation from contact with moisture
- Use a broom handle with a nail in the end to access hard to reach areas
- Provide vapour and moisture barriers to prevent condensation
Improve the Thermal Performance of Home Insulation
- Fit batts snugly leaving no gaps around ducts and pipes
- Make sure corners, junctions of wall-floor-ceiling are fully covered
- Isolate metal framing from contact with cladding
- Insulate window frames or install windows with thermal breaks
Home Insulation Clearance Requirements
Some appliances and fittings, such as recessed downlights and heater flues, require free space around them for the dissipation of heat, to reduce fire hazard. Insulation should not be placed against these fixtures.
- Recessed downlights – Minimum clearance of 100mm (200mm for halogen downlights), and 50mm from the transformer or driver, unless the rating marked on the fitting allows less
- Flues and exhaust fans – Minimum clearance of 25mm
- Electrical wiring – Keep wiring clear of insulation (check with electrician before installing insulation)
Condensation
Home insulation, correctly installed, can keep the interior surface temperature of ceilings and external walls above the dewpoint, preventing condensation on these surfaces. Condensation control involves preventing moist air from coming into contact with cold surfaces below the dewpoint of the air by one or more of the following means:
- Good ventilation of the moisture-laden air.
- Insulation to keep ceiling and wall temperatures above dewpoint.
- Heating to prevent indoor surfaces from cooling below the dewpoint.
Protect Insulation from Contact with Moisture
Masonry walls are not waterproof. In both brick veneer and double-brick wall construction a cavity between the external masonry wall and the internal lining keeps the internal lining dry. Moisture on the internal face of the external masonry wall can drain away through weepholes or evaporate into the cavity.
- Brick veneer construction – make sure the insulation remains within the frame. Use reflective foil, galvanized wire or building paper to keep the bulk insulation in place.
- Cavity masonry walls – restrain bulk insulation to maintain at least 30mm cavity.
- Existing wall cavities – use ‘cavity fill’ water-repellent loose-fill granular rockwool insulation. This material contains a water repelling agent to prevent absorption of moisture.
Sealed Air Space with Reflective Foil
- Reflective insulation adjacent to a solid surface without an airspace, has no insulative value and acts only as a vapour barrier. To add thermal resistance, reflective insulation must face a sealed air space.
- Maintain a sealed air space of at least 25 mm.
- Eliminate air movement between air spaces on either side of the foil.
- Overlap sheets by 150 mm and tape over joins; seal any gaps.
- Use face-of-wall brick ties instead of ties which penetrate the foil.
- Reflective surfaces should be kept clean and dust free, vertical installation is best for this.
Insulation Installation – Clearance Around Appliances and Fittings
Caution When Using Foil Products
- Keep foil products away from electrical power outlets or lights as they can conduct electricity through the aluminium metal reflective covering.
- Care must also be taken when installing under metal or tile roofs.
Wear Protective Clothing Before You Insulate
- When installing insulation in the roof space, it’s recommended to wear goggles, a dust mask, gloves, long pants and a long sleeve shirt.
Install instructions
How to install ceiling insulation
Do not start work until the site is safe!
Insulation batts installation - all work must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application for your roof insulation installation. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Start from the furthest point, ensuring the top plate (top of the wall) is covered and work back towards the access hatch of the ceiling. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label. Remember: the best house insulation performance will be achieved by following the manufacturers guidelines.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Make sure when installing roof insulation that you leave sufficient clearances around recessed lights, extractor fans, chimney elements and piping as appropriate.
- Where possible, place insulation under electrical cables and ductwork.
- Use any off-cuts to fill voids.
- Glue or fix insulation to the back of the access lid or hatch.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height of insulation. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed installing your home insulation, make sure you keep a copy of the product specification together with the documentation of your house.
How to install wall insulation
Do not commence installing insulation until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999-1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Work progressively around the perimeter of the building/room. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required. When cutting* to fill a void, oversize by around 10mm to ensure a snug fit. Do not leave folds or compress the insulation material.
- Fill gaps around lintels, double framing, windows and doors with off-cuts.
- Trim and place product around vents to allow ventilation systems to operate as intended.
- Shape and fit insulation behind electrical wiring and plumbing work.
- Use string to hold in place (if required).
- Ensure insulation does not protrude beyond the line of the studs.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed your insulation installation make sure you keep a copy of the product specification with the documentation of your house.
How to install underfloor insulation
Do not start work until the site is safe!
Insulation installation must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
The insulation should always be fitted with strapping. - If fitted to fold down, the fold should be no more than 75mm below the bottom of the product.
- Start from the furthest point ensuring the bottom plate is covered and work back towards the access entrance of the underfloor.
- When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Install the insulation in accordance with AS3999:1992, ensuring appropriate clearances from recessed lights, plumbing, extractor fans, chimney elements and piping.
- Refer to relevant standard for guidance regarding placement of insulation and stapling around electrical wiring.
- EXTREME CAUTION REQUIRED. If insulation is covering any wires, apply the Electrical Hazard labels at that point
Step 3
- Place long edge side of the insulation first neatly into the joist/underside of floor intersection
- Pressure fit the body of the insulation flush up under the floor
- Fold the opposite edge down so that a snug fit is achieved
- Leave no gaps between the insulation and the framing and the underside of the floor
- Fix strapping across the underside of the insulation batt
- Each insulation batt should have three runs of strapping applied, one at approx. 100mm from each end and one diagonal or across the centre of the insulation batt.
- Always ensure the insulation has a snug fit. Refer to the tips and tricks for techniques to reach tight spaces.
Step 4
- Once you have finished installing the insulation make sure you keep a copy of the product specification with the documentation of your house.
Top tips and tricks
Preload the ceiling before plastering
If you are building a new home it is a good idea to get the insulation above the ceiling before the roof space is enclosed.
For hard to reach areas, use a broom handle with a nail through the tip to spike the batt and position it.
You need ventilation while you work. If the roof is tiled, kick back some tiles for ventilation.
Try to avoid installing on a hot day, but if you are start nice and early and drink plenty of water throughout the day.
Use thick plywood or a wooden plank to support yourself over the ceiling rafters. This is more comfortable for your knees than kneeling on the rafters.
Knauf Insulation Earthwool Insulation is a new generation of softer, safer and more environmentally friendly glasswool insulation specifically designed for DIY installation.
We don't have an installation guide for this product yet. Need a hand? Call 1300 729 639.
We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.
Full delivery & pickup info →We collect verified reviews on Trustpilot across all our products and service.
Read all on Trustpilot →Similar options for this application, compared on price per m² and R-value.
Bradford SoundScreen Acoustic Insulation Batts
- Wall options from R2.0 to R3.1 to match your comfort target
- Australian made, to Australian standards
Bradford Gold Batts Thermal Ceiling Insulation
- Choose from R2.5 to R4.1
- Australian made, to Australian standards
Bradford Gold Batts Hi-Performance Wall Insulation
- Wall options from R2.0 to R2.7 to match your comfort target
- Australian made, to Australian standards
Bradford Hi-Performance Gold Ceiling Batts
- Choose from R5.0 to R7.0, from temperate climates up to cold-climate performance
- Australian made, to Australian standards