Pro Clima Solitex Extasana Wrap
Pro Clima Solitex Extasana® Wrap
Pro Clima Solitex Extasana is intended for installation behind various standard wall cladding systems, such as cavity brick, fibre-cement, masonry, and other frequently used wall constructions. Pro Clima Solitex Extasana® is a UV-stabilised and durable weather-resistant barrier engineered with a non-permeable, waterproof TEEE film that is securely bonded between two layers of spun-bonded polypropylene at elevated temperatures. This vapour permeable wall wrap is suitable for use in BAL regions up to and including BAL-FZ, in accordance with AS 3959.Benefits of Pro Clima Solitex Extasana® Vapour Permeable Wall Wrap
- 180 days UV resistance & long-term durability
- Highly vapour permeable (Class 4)
- Weathertight & airtight weather resistive barrier (WRB)
- Next generation non-porous monolithic technology
5 Tips on Installing Pro Clima
Related Products
Request a quote
Pro Clima Solitex Extasana Wrap
Thanks, your request is on its way.
We’ll get back to you with pricing within one business hour.
| Length | Width | Area | Weight per roll |
|---|---|---|---|
| 50 m | 1.50 m | 75 m² | 11.6 kg |
| 36.5 m | 2.74 m | 100 m² | 16 kg |
Delivery form as listed on the pro clima data sheet.
PDF, opens in a new tab Metal Application Guide
PDF, opens in a new tab Timber Application Guide
PDF, opens in a new tab Safety Data Sheet
PDF, opens in a new tab Fire Test Report
PDF, opens in a new tab Warranty
PDF, opens in a new tab Flashing and dampcourse connection options
PDF, opens in a new tab Adhesion matrix
PDF, opens in a new tab Sealant compatibility and adhesion matrix
PDF, opens in a new tab
Timber frame
Summarised from the SOLITEX EXTASANA Application & Fixing Guide, Timber Frame (AUS, 03.06.2021). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)
- Make sure all studs are aligned and free from splinters, and check for nails, metal strapping or sharp framing edges that could wear through the membrane.
- Mark where the top edge of the membrane will go to get a suitable overlap onto the slab edge or flashing.
- Apply 5 to 6 staples in one top corner, unroll the membrane over the studs, pull it taut and fix the opposite top corner with 5 to 6 staples.
- Pull the membrane down taut at the centre and fix it with 2 to 3 staples at the bottom edge, then fix each bottom corner with 2 to 3 staples.
- Fix the membrane at each stud along the top edge with staples within 150 mm of the edge.
- Use galvanised or stainless steel staples at least 10 mm wide and at least 1.3 mm thick.
- Apply each following layer in an upside-down sequence compared to the bottom layer, overlapping by 150 mm along the printed white line.
- Tape the horizontal joints with at least TESCON EXTORA 60 mm, 30 mm onto each side of the joint, and press it with the PRESSFIX tool.
- Cut the membrane at the window reveals with 45° cuts to form 4 flaps, fold them into the reveal and cut them flush with the back edge of the framing.
- Staple the flaps at the rear edge of the reveal at 150 mm centres.
- Cover exposed framing at the corners of the sill with TESCON EXTOSEAL sill tape.
- Use a new piece of membrane on each face of the building and avoid rounded corners, which make batten installation difficult.
- Cut the second piece long enough to extend more than 50 mm around the corner, hold it with DUPLEX and press it into the corner with PRESSFIX.
- Tape the joint on a flat section of wall away from the corner, never directly in the corner.
- Fit a ROFLEX grommet of the correct size tightly over the pipe in a diamond orientation, then tape around it with TESCON EXTORA from the bottom edge, working anti-clockwise so upper layers lap over lower ones.
- Patch all exposed staple holes with TESCON EXTORA.
The guide states SOLITEX EXTASANA can be installed according to AS 4200.2-2017 or as per the pro clima installation method in the guide.
Metal frame
Summarised from the SOLITEX EXTASANA Application & Fixing Guide, Metal Frame (AUS, 20.10.2021). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)
- Clean all sharp edges and burrs from the steel framing so the membrane is not damaged during installation or in service.
- Measure and mark where the top edge of the membrane will be, allowing for the bottom edge flashing detail.
- Apply DUPLEX double-sided tape to the studs at suitable intervals, press it with PRESSFIX and remove the release paper.
- DUPLEX only holds the membrane in place until the facade mounting system is installed; it is not a long-term fixing.
- Pull the membrane taut along the top edge, adhering it to the DUPLEX as you go, then adhere the bottom edge at the centre while applying tension.
- Pull taut and adhere the bottom corners, applying moderate pressure with the PRESSFIX tool.
- Apply successive layers in an upside-down sequence with slight tension, overlapping 150 mm along the printed white line.
- Tape the horizontal joints with at least TESCON EXTORA 60 mm and press it with the PRESSFIX tool.
- Cut the membrane at the reveals with 45° cuts to form 4 flaps, fix them into the reveal with DUPLEX at the rear edge and cut them flush with the back edge of the metal framing.
- Cover exposed framing at the sill corners with TESCON EXTOSEAL, extending it at least 150 mm up the jambs.
- For brick veneer, hold the membrane temporarily with galvanised hex screws and washers at 300 mm centres before the brickwork.
- Use TESCON NAIDECK to seal temporary fixings and other attachments fixed to the studs through the membrane.
Insulation Installation - Do It Yourself
Many homeowners choose to install their own insulation. Done properly, it can be a rewarding DIY project that makes your home more comfortable and energy efficient. To get the best results, it’s important to install insulation batts correctly. Otherwise, their performance can be reduced by up to 50%. If you choose to take on the home insulation installation yourself, we strongly recommend that you familiarise yourself with the proper process. Make sure you check the relevant standards prior to commencing the installation.
Using a sharp knife, and a thin plank of wood as a guide, can make cutting insulation batts easier. Experienced insulation installers will often size up the cut with a glance and press the insulation against a vertical timber wall stud before cutting the batt to the desired width or length. This can save time, but care must be taken to ensure that you keep the knife blade well clear of any wiring or other appliances.
General install tips
DIY Install Tips for Beginners
The following principles of installing insulation will ensure the best possible performance from home insulation.
- Avoid gaps in insulation
- Do not compress bulk home insulation
- Allow clearance around appliances and fittings
- Protect your home insulation from contact with moisture
- Use a broom handle with a nail in the end to access hard to reach areas
- Provide vapour and moisture barriers to prevent condensation
Improve the Thermal Performance of Home Insulation
- Fit batts snugly leaving no gaps around ducts and pipes
- Make sure corners, junctions of wall-floor-ceiling are fully covered
- Isolate metal framing from contact with cladding
- Insulate window frames or install windows with thermal breaks
Home Insulation Clearance Requirements
Some appliances and fittings, such as recessed downlights and heater flues, require free space around them for the dissipation of heat, to reduce fire hazard. Insulation should not be placed against these fixtures.
- Recessed downlights – Minimum clearance of 25mm
- Flues and exhaust fans – Minimum clearance of 25mm
- Electrical wiring – Keep wiring clear of insulation (check with electrician before installing insulation)
Condensation
Home insulation, correctly installed, can keep the interior surface temperature of ceilings and external walls above the dewpoint, preventing condensation on these surfaces. Condensation control involves preventing moist air from coming into contact with cold surfaces below the dewpoint of the air by one or more of the following means:
- Good ventilation of the moisture-laden air.
- Insulation to keep ceiling and wall temperatures above dewpoint.
- Heating to prevent indoor surfaces from cooling below the dewpoint.
Protect Insulation from Contact with Moisture
Masonry walls are not waterproof. In both brick veneer and double-brick wall construction a cavity between the external masonry wall and the internal lining keeps the internal lining dry. Moisture on the internal face of the external masonry wall can drain away through weepholes or evaporate into the cavity.
- Brick veneer construction – make sure the insulation remains within the frame. Use reflective foil, galvanized wire or building paper to keep the bulk insulation in place.
- Cavity masonry walls – restrain bulk insulation to maintain at least 30mm cavity.
- Existing wall cavities – use ‘cavity fill’ water-repellent loose-fill granular rockwool insulation. This material contains a water repelling agent to prevent absorption of moisture.
Sealed Air Space with Reflective Foil
- Reflective insulation adjacent to a solid surface without an airspace, has no insulative value and acts only as a vapour barrier. To add thermal resistance, reflective insulation must face a sealed air space.
- Maintain a sealed air space of at least 25 mm.
- Eliminate air movement between air spaces on either side of the foil.
- Overlap sheets by 150 mm and tape over joins; seal any gaps.
- Use face-of-wall brick ties instead of ties which penetrate the foil.
- Reflective surfaces should be kept clean and dust free, vertical installation is best for this.
Insulation Installation – Clearance Around Appliances and Fittings
Caution When Using Foil Products
- Keep foil products away from electrical power outlets or lights as they can conduct electricity through the aluminium metal reflective covering.
- Care must also be taken when installing under metal or tile roofs.
Wear Protective Clothing Before You Insulate
- When installing insulation in the roof space, it’s recommended to wear goggles, a dust mask, gloves, long pants and a long sleeve shirt.
Install instructions
How to install ceiling insulation
Do not start work until the site is safe!
Insulation batts installation - all work must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application for your roof insulation installation. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Start from the furthest point, ensuring the top plate (top of the wall) is covered and work back towards the access hatch of the ceiling. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label. Remember: the best house insulation performance will be achieved by following the manufacturers guidelines.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Make sure when installing roof insulation that you leave sufficient clearances around recessed lights, extractor fans, chimney elements and piping as appropriate.
- Where possible, place insulation under electrical cables and ductwork.
- Use any off-cuts to fill voids.
- Glue or fix insulation to the back of the access lid or hatch.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height of insulation. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed installing your home insulation, make sure you keep a copy of the product specification together with the documentation of your house.
How to install wall insulation
Do not commence installing insulation until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999-1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Work progressively around the perimeter of the building/room. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required. When cutting* to fill a void, oversize by around 10mm to ensure a snug fit. Do not leave folds or compress the insulation material.
- Fill gaps around lintels, double framing, windows and doors with off-cuts.
- Trim and place product around vents to allow ventilation systems to operate as intended.
- Shape and fit insulation behind electrical wiring and plumbing work.
- Use string to hold in place (if required).
- Ensure insulation does not protrude beyond the line of the studs.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed your insulation installation make sure you keep a copy of the product specification with the documentation of your house.
How to install underfloor insulation
Do not start work until the site is safe!
Insulation installation must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
The insulation should always be fitted with strapping. - If fitted to fold down the fold should be no more that 75mm below the bottom of the product.
- Start from the furthest point ensuring the bottom plate is covered and work back towards the access entrance of the underfloor.
- When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Install the insulation in accordance with AS3999:1992, ensuring appropriate clearances from recessed lights, plumbing, extractor fans, chimney elements and piping.
- Refer to relevant standard for guidance regarding placement of insulation and stapling around electrical wiring.
- EXTREME CAUTION REQUIRED. If insulation is covering any wires, apply the Electrical Hazard labels at that point
Step 3
- Place long edge side of the insulation first neatly into the joist/underside of floor intersection
- Pressure fit the body of the insulation flush up under the floor
- Fold the opposite edge down so that a snug fit is achieved
- Leave no gaps between the insulation and the framing and the underside of the floor
- Fix strapping across the underside of the insulation batt
- Each insulation batt should have three runs of strapping applied, one at approx. 100mm from each end and one diagonal or across the centre of the insulation batt.
- Always ensure the insulation has a snug fit. Refer to the tips and tricks for techniques to reach tight spaces.
Step 4
- Once you have finished installing the insulation make sure you keep a copy of the product specification with the documentation of your house.
Top tips and tricks
Preload the ceiling before plastering
If you are building a new home it is a good idea to get the insulation above the ceiling before the roof space is enclosed.
For hard to reach areas, use a broom handle with a nail through the tip to spike the batt and position it.
You need ventilation while you work. If the roof is tiled, kick back some tiles for ventilation.
Try to avoid installing on a hot day, but if you are start nice and early and drink plenty of water throughout the day.
Use thick plywood or a wooden plank to support yourself over the ceiling rafters. This is more comfortable for your knees than kneeling on the rafters.
Knauf Insulation Earthwool Insulation is a new generation of softer, safer and more environmentally friendly glasswool insulation specifically designed for DIY installation.
Install guides for this product are below. Need a hand? Call 1300 729 639.
We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.
Full delivery & pickup info →We collect verified reviews on Trustpilot across all our products and service.
Read all on Trustpilot →Similar options for this application, compared on price per m² and R-value.
Pro Clima Pressfix XL Pressing Tool
- Seals joins and laps to stop air and vapour leaks
- Makes cutting and fitting faster and cleaner
Pro Clima Tescon Extoseal® Sill Tape
- Purpose-made fixings for a secure, correct installation
- Seals joins and laps to stop air and vapour leaks
Pro Clima Tescon Extora® Sealing Tape
- Intelligent vapour control that protects the build-up from condensation
- Seals joins and laps to stop air and vapour leaks
Pro Clima Solitex Mento Plus Wrap
- Class 4 vapour permeable roof underlay, water and air barrier (AS 4200.1)
- Up to 180 days UV exposure (ASTM G155)