Pro Clima Solitex Mento Plus Wrap

Get 5% off as a trade customer. Open an instant trade account
Location Queensland
Dimensions (m) 50m x 3m
Call for price
☎ 1300 729 639

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Class 4 vapour permeable roof underlay, water and air barrier (AS 4200.1)
  • Up to 180 days UV exposure (ASTM G155)
  • Suitable up to and including BAL FZ (AS 3959)
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639

pro clima SOLITEX MENTO® PLUS is a roof weather resistive barrier (WRB), laid as a sarking membrane under tile, metal and slate roofs. It protects the roof and building envelope from the weather during construction, while internal moisture escapes through its vapour permeable, non-porous TEEE layer. The TEEE film is laminated between two layers of spun bonded polypropylene and reinforced with a polypropylene scrim.

Where to use it

  • Tile, metal and slate roofs. It has a medium duty classification to AS 4200.1; pro clima refers to AS 4200.2 for installation.
  • Roof pitch: pro clima does not recommend installing SOLITEX MENTO under 5° roof pitch, as this can result in ponding.
  • Rafter spacing: no more than 1 m.
  • Bushfire-prone areas: suitable for BAL regions up to and including BAL FZ in accordance with AS 3959.
  • This is a roof membrane. Where the roof meets a wall, the application guide laps the wall WRB, SOLITEX EXTASANA, 150 mm onto SOLITEX MENTO and tapes the joint with TESCON EXTORA.

Performance

  • Vapour control: Class 4, vapour permeable (AS 4200.1). Vapour permeance 1.429 µg/N·s (ASTM E96 Method B).
  • Water control: water barrier (AS 4200.1), more than 2,500 mm (EN ISO 811).
  • Air control: air barrier (AS 4200.1), air permeability below 0.055 m³/(m²·h·50 Pa) (EN 12114).
  • Fire: flammability index below 5 (AS 1530.2). pro clima states the membrane is deemed non-combustible because it is less than 1 mm thick and has a flammability index below 5 (NCC 2025 Vol 1 C2D10(6)(f) and Vol 2 H3D2(1)(f)).
  • Withstands temperatures up to 100 °C and down to -40 °C behind external claddings.
  • Thickness 0.60 mm, surface weight 175 g/m², tensile strength 10.1 / 7.1 kN/m (machine / lateral direction).

Sizes we sell

  • 50 m x 1.50 m roll: 75 m², 13 kg.
  • 50 m x 3.00 m roll: 150 m², 26 kg.
  • SOLITEX MENTO PLUS connect, 50 m x 1.50 m roll: 75 m², 13 kg. It has an integrated adhesive connection strip for faster installation; its data sheet lists the same technical values as the standard roll.

Installation notes

  • Designed to withstand up to 180 days of UV exposure before cladding. The application guide allows its use as a temporary roof cover for up to 180 days when TESCON NAIDECK seals the fixings. Detail the roof cladding so that no direct sunlight reaches the membrane in service.
  • Lay it horizontally, parallel to the eave, taut and with the printed side facing the installer. Overlap each layer by 150 mm along the printed white line.
  • How the laps are sealed depends on the roof pitch (above 15°, 10° to 15°, 5° to 10°). Counter battens must be at least 20 mm high for drainage and ventilation.
  • Install to AS 4200.2-2017 or the pro clima method. The Installation tab has the full steps.

Good to know

  • Meets the requirements of AS 4200.1 and is suitable for use in Australia.
  • Electrically non-conductive.
  • Keep the membrane away from grinding sparks.

5 Tips on Installing Pro Clima

1
Technical data
BrandPro Clima
Vapour permeance classClass 4, vapour permeable (AS 4200.1); 1.429 µg/N·s (ASTM E96 Method B)
Water barrierWater barrier (AS 4200.1)
Air barrierAir barrier (AS 4200.1)
UV exposureUp to 180 days before cladding (ASTM G155)
Bushfire useUp to and including BAL FZ (AS 3959)
Flammability index< 5 (AS 1530.2)
Roll sizes
ProductLengthWidthAreaWeight per roll
SOLITEX MENTO PLUS50 m1.50 m75 m²13 kg
SOLITEX MENTO PLUS50 m3.00 m150 m²26 kg
SOLITEX MENTO PLUS connect50 m1.50 m75 m²13 kg

Delivery form as listed on the pro clima data sheet.

Roofs

Summarised from the SOLITEX MENTO Application Guide (AUS, 11.06.2021). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Prepare the roof framing
  • Make sure all rafters or trusses are aligned and free from splinters.
  • Mark where the top edge of the membrane will go so there is enough overlap for the eave detail you have designed.
2Fix the first layer
  • Pull the top edge taut and staple within the overlap zone, so fewer staple holes are exposed to water run-off.
  • After fixing two points along the top edge, pull the membrane down taut at the centre and fix it with 2 to 3 staples, then fix each bottom corner with 2 to 3 staples.
3Fit the counter battens
  • Fix counter battens to hold the first layer, finishing them 50 mm short of the overlap line so they do not get in the way of the joint.
  • Use counter battens at least 20 mm high for drainage and ventilation; 45 mm battens give extra summer heat removal.
4Overlap the next layer
  • Overlap each layer by 150 mm, using the printed white line as a guide.
  • Keep membranes away from grinding sparks.
5Seal joints by pitch
  • Above 15°, apply at least TESCON EXTORA 60 mm to the horizontal joints with 30 mm onto each side and press it with the PRESSFIX tool.
  • From 10° to 15°, join the overlap with DUPLEX placed 5 to 10 mm from the overlap line, then tape over it with TESCON EXTORA.
  • From 5° to 10°, lay the membrane over solid sheathing, place the top layer onto a bead of about 5 mm ORCON CLASSIC and seal the overlap with TESCON EXTORA 60 mm.
6Seal fixings on low pitches
  • At pitches of 10° or less, fit TESCON NAIDECK between the counter battens and the membrane.
  • Screw fix the counter battens so the TESCON NAIDECK is compressed and seals around the fixings.
7Tape exposed staples
  • Seal any staples that are not hidden under an overlap with a patch of TESCON EXTORA.

The guide states SOLITEX MENTO 5000, PLUS and ULTRA can be installed according to AS 4200.2-2017 or as per the pro clima installation method in the guide.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
ReturnsWithin 30 days
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
4.9 from 590 Trustpilot reviews