Autex Greenstuf Polyester Baffleblock Insulation Rolls100.0 mm

Get 10% off as a trade customer. Open an instant trade account
A minimum order quantity of 200 m² applies.
Allow 7 to 10 days for delivery.
Location Victoria
Thickness 100mm
Quantity calculator
10.0 m²
You need
packs
Actual area - m²
Total inc GST
-

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Non-itch and safe to handle, so no gloves or mask needed and great for DIY
  • Strong acoustic performance that cuts noise transfer
  • Covers 10 m² per pack
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639

Greenstuf Polyester Baffleblock Insulation

By installing GreenStuf® Baffle block Insulation above new or existing Sound Transmission Rated (STC) walls you can enhance the acoustic privacy between spaces. GreenStuf® Baffleblock® is easy to install and will mould itself around existing ducting and services, eliminating gaps and holes as potential sound paths. The performance and design of GreenStuf® BaffleBlock Insulation has been engineered to supply a tested and proven sound control system. GreenStuf Baffleblock Insulation is a 100% polyester acoustic insulation product designed to be layer stacked above partition walls to reduce sound transmission through the ceiling plenum space and is supplied as rolls pre-cut to 600mm wide.

Installing Baffle Block Insulation

Greenstuf Baffleblock from Autex is designed for use above new or existing STC rated partition walls to enhance the acoustic privacy between spaces. The rolls must be installed with at least enough compression to ensure stack stability and a tight fit to all surfaces including concrete slab, ceiling or the floor above. No gaps to be allowed through the stack. Baffleblock can be installed to a height of 1m without specialist design considerations.

Above this height consideration must be given to the stack stability and weight loading restrictions on the ceiling tiles and grid system. Other options are available for plenum heights above 1m. Where the ceiling plenum is used as an active return for the air conditioning system, ensure airflow is not significantly reduced. It is recommended you consult the Mechanical Services Engineer to ensure the use of an acoustic block will not result in a loss of effective air movement. Existing services, ducting, ceiling grid supports and fire control and detection devices must not be affected by the installation. Acoustic baffle block should not be used where temperatures exceed 160ºC. Where flues or similar heat emitting items pass through the insulation, a 200mm venting gap should be left between that item and the insulation.

1
Technical data
BrandAutex
MaterialPolyester
Applicationacoustic
Density10 kg/m³
FireCombustible
Pack contents2 rolls, 600 mm wide x 8.33 m long (10.00 m² per pack)
Surface mass1000 gsm
Acoustic performanceInsertion loss 12.90 dBA at 10% stack compression, 14.10 dBA at 33%, 15.20 dBA at 40%
Early fire hazard indicesIgnitability 0, Heat evolved 0, Spread of flame 0, Smoke developed 3 (AS 1530.3)
Fire classificationGroup 1, SMOGRA RC less than 100 m²/s² (AS ISO 9705:2003, assessed to AS 5637.1:2015)
Service temperatureNot for use where temperatures exceed 160°C
SuitsCeiling plenum above new or existing RW rated partition walls

Denser batts (higher kg/m³) hold more mass, so they absorb more sound and cut noise transfer between rooms better. NRC rates that absorption from 0 to 1.

Insertion loss at different stack compressions
Frequency10% compression (11 kg/m³)33% compression (15 kg/m³)40% compression (16 kg/m³)
63 Hz5.225.766.73
125 Hz7.758.389.34
250 Hz7.278.249.01
500 Hz13.1514.3515.64
1000 Hz15.2517.0118.42
2000 Hz16.5618.7120.17
4000 Hz19.5322.5624.21
8000 Hz18.3020.5421.78
Insertion loss (dBA)12.9014.1015.20

Tested through the 600 mm section of the material; installed density is product weight divided by nominal thickness.

Step by step

Summarised from the GreenStuf Baffleblock, Data Sheet (Australian edition, GS_AU_DS_Baffleblock-Datasheet_April19_CT). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Check with other trades
  • Consult the HVAC installer or engineer before you start, so the active return of the air conditioning keeps effective air movement.
  • Make sure existing services, ducting, ceiling grid supports and fire control and detection devices are not affected by the installation.
2Stack above the wall
  • Remove all packaging.
  • Install the rolls as a layer stack above the RW rated partition wall.
  • Use enough compression for stack stability and a tight fit to all surfaces, including the slab, roof or floor above.
3Close every gap
  • Allow no gaps through the stack.
  • Fill around ducting, services and structural components with small pieces.
4Keep within height and heat limits
  • Stacks up to 1 m high need no specialist design; above 1 m, consider stack stability and the weight loading on the ceiling tiles and grid.
  • Do not use where temperatures exceed 160°C, and leave a 200 mm venting gap where flues or similar heat-emitting items pass through the insulation.

Taken from the installation and application sections of the data sheet; Autex publishes no separate Baffleblock installation guide.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
ReturnsWithin 30 days
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
4.9 from 590 Trustpilot reviews

We collect verified reviews on Trustpilot across all our products and service.

Read all on Trustpilot →