Expol Polystyrene Underfloor Insulation60.0 mm
EXPOL Underfloor Insulation is a rigid expanded polystyrene (EPS) panel that fits between the joists of a timber floor. Each 60 mm panel is rated R1.4 and is concertina cut on both edges, so it compresses for a snug fit between the joists. It can go into new homes before the floor goes down, or be retrofitted under existing floors.
Where to use it
Under suspended timber floors in new and existing houses, fitted between the floor joists. BRANZ Appraisal No. 871 finds it suitable for exposed underfloors without a lining when installed to Expol's instructions, with fixings in wind exposed situations. See all underfloor insulation.
Thermal performance
- R1.40 at 60 mm (ASTM C518-04, AS 4859.1)
- Complies with AS/NZS 4859.1
- BRANZ Appraisal No. 871 (2026) assesses it against NCC 2022 Volume Two, H6P1 and Housing Provisions 13.2.2. More than one layer may be needed to reach the minimum R-value required for your home, which the designer and installer must check.
- Expol states its insulation performance is not affected by ageing or moisture.
Sizes we sell
| Panel (mm) | Panels per bag | Coverage per bag |
|---|---|---|
| 1200 x 410 x 60 | 11 | 5.41 m² |
| 1200 x 470 x 60 | 10 | 5.64 m² |
| 1200 x 560 x 60 | 9 | 6.05 m² |
Measure the gap between your joists before ordering. Joists vary, so measure a few; a job may need more than one panel width. If a panel is too wide, slice down the concertina edge, leaving it about 5 mm oversize. The nominal length is between 1200 mm and 1240 mm; the widths do not vary.
Installation notes
- Keep 200 mm clear of metal heating flues, recessed downlights and exhaust fans, and 50 mm clear of brick and concrete chimneys.
- Fit each panel hard against the underside of the floor so there is no air gap. Fill all gaps and make butt joins tight.
- PVC cables must not touch the panels. Sleeve them in EXPOL Wireguard, and never use a staple gun.
- Fix each panel with two EXPOL fixings at opposite corners. BRANZ requires EXPOL nylon brackets to achieve the 50 year serviceable life, and in underfloors exposed to wind.
- Notch around pipes with a sharp knife and leave 100 mm clearance for maintenance.
The Installation tab has the step by step guide.
Good to know
- Combustible: BRANZ classifies it as combustible, for use only where combustible materials are permitted under NCC Volume Two. In bushfire prone areas, NCC Volume Two H7D4 applies. It is made from flame retardant bead, with a Spread of Flame Index of 0 and a Smoke Developed Index of 5 (AS/NZS 1530.3:1999).
- Store bags under cover, out of sunlight, with nothing heavy stacked on them. Panels can get wet before installation but should be dry when installed; insulation that becomes damp must be removed and the cause fixed.
- Serviceable life of at least 50 years in a maintained building (BRANZ), and a 50 year limited product warranty from Expol.
- Non-allergenic and non-irritating. Panels are fully recyclable at a StyroCycle drop off site.
Request a quote
Expol Polystyrene Underfloor Insulation
Thanks, your request is on its way.
We’ll get back to you with pricing within one business hour.
Step by step
Summarised from the EXPOL Underfloor Insulation brochure, Installation Instructions (August 2023); clearances from the EXPOL DIY Step Guide (2026). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)
- Measure your joists, for example with the EXPOL Easy Measure Ruler from your stockist, and choose the panel width that fits.
- Joist sizes can vary, so measure more than one. You may need a few different panel sizes for the job.
- If the panel is too wide, slice down the concertina edge, leaving the panel about 5 mm oversize for a firm fit.
- Place EXPOL Wireguard around any cables that come in direct contact with EXPOL.
- Do not use a staple gun to fix the Wireguard, and always take care around electrical wiring.
- Leave at least 200 mm around metal heating flues, recessed downlights and exhaust fans.
- Leave 50 mm around brick or concrete chimneys.
- Slide the panel between the joists. The concertina cut is designed to give a tight fit.
- Push the panel hard against the underside of the floor so there are no air gaps.
- Once the panel is installed, tack two EXPOL fixings in opposite corners so the panel stays in place.
- The nylon fixings come with a stainless steel nail, so you simply nail two per panel.
- Use a sharp knife to cut the panel and notch it around pipes, plumbing and other obstacles.
- Leave 100 mm clearance around pipes and plumbing for future maintenance.
Insulation Installation - Do It Yourself
Many homeowners choose to install their own insulation. Done properly, it can be a rewarding DIY project that makes your home more comfortable and energy efficient. To get the best results, it’s important to install insulation batts correctly. Otherwise, their performance can be reduced by up to 50%. If you choose to take on the home insulation installation yourself, we strongly recommend that you familiarise yourself with the proper process. Make sure you check the relevant standards prior to commencing the installation.
Using a sharp knife, and a thin plank of wood as a guide, can make cutting insulation batts easier. Experienced insulation installers will often size up the cut with a glance and press the insulation against a vertical timber wall stud before cutting the batt to the desired width or length. This can save time, but care must be taken to ensure that you keep the knife blade well clear of any wiring or other appliances.
General install tips
DIY Install Tips for Beginners
The following principles of installing insulation will ensure the best possible performance from home insulation.
- Avoid gaps in insulation
- Do not compress bulk home insulation
- Allow clearance around appliances and fittings
- Protect your home insulation from contact with moisture
- Use a broom handle with a nail in the end to access hard to reach areas
- Provide vapour and moisture barriers to prevent condensation
Improve the Thermal Performance of Home Insulation
- Fit batts snugly leaving no gaps around ducts and pipes
- Make sure corners, junctions of wall-floor-ceiling are fully covered
- Isolate metal framing from contact with cladding
- Insulate window frames or install windows with thermal breaks
Home Insulation Clearance Requirements
Some appliances and fittings, such as recessed downlights and heater flues, require free space around them for the dissipation of heat, to reduce fire hazard. Insulation should not be placed against these fixtures.
- Recessed downlights – Minimum clearance of 25mm
- Flues and exhaust fans – Minimum clearance of 25mm
- Electrical wiring – Keep wiring clear of insulation (check with electrician before installing insulation)
Condensation
Home insulation, correctly installed, can keep the interior surface temperature of ceilings and external walls above the dewpoint, preventing condensation on these surfaces. Condensation control involves preventing moist air from coming into contact with cold surfaces below the dewpoint of the air by one or more of the following means:
- Good ventilation of the moisture-laden air.
- Insulation to keep ceiling and wall temperatures above dewpoint.
- Heating to prevent indoor surfaces from cooling below the dewpoint.
Protect Insulation from Contact with Moisture
Masonry walls are not waterproof. In both brick veneer and double-brick wall construction a cavity between the external masonry wall and the internal lining keeps the internal lining dry. Moisture on the internal face of the external masonry wall can drain away through weepholes or evaporate into the cavity.
- Brick veneer construction – make sure the insulation remains within the frame. Use reflective foil, galvanized wire or building paper to keep the bulk insulation in place.
- Cavity masonry walls – restrain bulk insulation to maintain at least 30mm cavity.
- Existing wall cavities – use ‘cavity fill’ water-repellent loose-fill granular rockwool insulation. This material contains a water repelling agent to prevent absorption of moisture.
Sealed Air Space with Reflective Foil
- Reflective insulation adjacent to a solid surface without an airspace, has no insulative value and acts only as a vapour barrier. To add thermal resistance, reflective insulation must face a sealed air space.
- Maintain a sealed air space of at least 25 mm.
- Eliminate air movement between air spaces on either side of the foil.
- Overlap sheets by 150 mm and tape over joins; seal any gaps.
- Use face-of-wall brick ties instead of ties which penetrate the foil.
- Reflective surfaces should be kept clean and dust free, vertical installation is best for this.
Insulation Installation – Clearance Around Appliances and Fittings
Caution When Using Foil Products
- Keep foil products away from electrical power outlets or lights as they can conduct electricity through the aluminium metal reflective covering.
- Care must also be taken when installing under metal or tile roofs.
Wear Protective Clothing Before You Insulate
- When installing insulation in the roof space, it’s recommended to wear goggles, a dust mask, gloves, long pants and a long sleeve shirt.
Install instructions
How to install ceiling insulation
Do not start work until the site is safe!
Insulation batts installation - all work must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application for your roof insulation installation. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Start from the furthest point, ensuring the top plate (top of the wall) is covered and work back towards the access hatch of the ceiling. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label. Remember: the best house insulation performance will be achieved by following the manufacturers guidelines.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Make sure when installing roof insulation that you leave sufficient clearances around recessed lights, extractor fans, chimney elements and piping as appropriate.
- Where possible, place insulation under electrical cables and ductwork.
- Use any off-cuts to fill voids.
- Glue or fix insulation to the back of the access lid or hatch.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height of insulation. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed installing your home insulation, make sure you keep a copy of the product specification together with the documentation of your house.
How to install wall insulation
Do not commence installing insulation until the site is safe!
Installation must be completed to the requirements of relevant standard: AS3999-1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
Work progressively around the perimeter of the building/room. - When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required. When cutting* to fill a void, oversize by around 10mm to ensure a snug fit. Do not leave folds or compress the insulation material.
- Fill gaps around lintels, double framing, windows and doors with off-cuts.
- Trim and place product around vents to allow ventilation systems to operate as intended.
- Shape and fit insulation behind electrical wiring and plumbing work.
- Use string to hold in place (if required).
- Ensure insulation does not protrude beyond the line of the studs.
Step 3
- Always make sure your insulation has a snug fit, with a uniform finished height. Check tips and tricks for good techniques in achieving this.
Step 4
- Once you have completed your insulation installation make sure you keep a copy of the product specification with the documentation of your house.
How to install underfloor insulation
Do not start work until the site is safe!
Insulation installation must be completed to the requirements of relevant standard: AS3999:1992
Step 1
- Ensure you have the right product for the application. Check that you have the correct R-Value required on the drawings/plans.
- Check the joist width to determine the correct insulation batt width. (e.g. 430mm or 580mm)
The insulation should always be fitted with strapping. - If fitted to fold down the fold should be no more that 75mm below the bottom of the product.
- Start from the furthest point ensuring the bottom plate is covered and work back towards the access entrance of the underfloor.
- When installing, energise each batt by giving it a light shake and gently bouncing it on its side, to help the batt expand to the thickness specified on the label.
Step 2
- The insulation may be trimmed to appropriate sizes if required.
- Install the insulation in accordance with AS3999:1992, ensuring appropriate clearances from recessed lights, plumbing, extractor fans, chimney elements and piping.
- Refer to relevant standard for guidance regarding placement of insulation and stapling around electrical wiring.
- EXTREME CAUTION REQUIRED. If insulation is covering any wires, apply the Electrical Hazard labels at that point
Step 3
- Place long edge side of the insulation first neatly into the joist/underside of floor intersection
- Pressure fit the body of the insulation flush up under the floor
- Fold the opposite edge down so that a snug fit is achieved
- Leave no gaps between the insulation and the framing and the underside of the floor
- Fix strapping across the underside of the insulation batt
- Each insulation batt should have three runs of strapping applied, one at approx. 100mm from each end and one diagonal or across the centre of the insulation batt.
- Always ensure the insulation has a snug fit. Refer to the tips and tricks for techniques to reach tight spaces.
Step 4
- Once you have finished installing the insulation make sure you keep a copy of the product specification with the documentation of your house.
Top tips and tricks
Preload the ceiling before plastering
If you are building a new home it is a good idea to get the insulation above the ceiling before the roof space is enclosed.
For hard to reach areas, use a broom handle with a nail through the tip to spike the batt and position it.
You need ventilation while you work. If the roof is tiled, kick back some tiles for ventilation.
Try to avoid installing on a hot day, but if you are start nice and early and drink plenty of water throughout the day.
Use thick plywood or a wooden plank to support yourself over the ceiling rafters. This is more comfortable for your knees than kneeling on the rafters.
Knauf Insulation Earthwool Insulation is a new generation of softer, safer and more environmentally friendly glasswool insulation specifically designed for DIY installation.
Install guides for this product are below. Need a hand? Call 1300 729 639.
We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.
Full delivery & pickup info →Answer a few quick questions, or describe your job in your own words, and wAIse checks whether this R1.4 product fits and compares it with two alternatives.
We collect verified reviews on Trustpilot across all our products and service.
Read all on Trustpilot →Similar options for this application, compared on price per m² and R-value.
Knauf Earthwool Sound Shield Insulation Batts
- Available from R2 to R4 to suit different climates
- Softer to handle than standard glasswool, thanks to the ECOSE bio-based binder
Knauf Earthwool Ceiling Insulation Batts
- Choose from R3 to R8, from temperate climates up to cold-climate performance
- Softer to handle than standard glasswool, thanks to the ECOSE bio-based binder
Bradford SoundScreen Acoustic Insulation Batts
- Wall options from R2 to R3.1 to match your comfort target
- Australian made, to Australian standards
Polyester Underfloor Insulation Rolls
- No special clothing, gloves or mask needed to install, according to the safety data sheet
- Underfloor options from R2 to R4