Black Friday SaleUp to 15% off big brands.Shop the sale →

Kingspan Air-Cell Permishield XV 70 Insulation7.2mm

Location Victoria
Dimensions 1350mm x 22.25m
Quantity calculator
30.0 m²
You need
rolls
Actual area - m²
Total inc GST
-

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Weathertight air barrier that still lets the structure breathe, controlling moisture and draughts
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639
Complete your order

Kingspan Air-Cell Permishield XV 70 (previously Permishield 65)

Australian-made Kingspan Air-Cell Permishield® XV 70 is a vapour-permeable barrier and insulation wrapped up in a single product. Kingspan AIR-CELL Permishield is designed specifically for use in framed and reverse brick veneer walls behind lightweight cladding materials that require vapour permeance. Manufactured with a patented closed-cell structure sandwiched by reflective foil surfaces and pierced with tiny, evenly-spaced breather holes, Kingspan AIR-CELL Permishield allows building professionals to do away with the traditional sarking-plus-batts combination in order to help achieve thermal compliance as well as satisfy vapour permeance.

The benefits of Kingspan Air-Cell Permishield XV 70

  • Australian made
  • Fibre-free, non-allergenic, non-irritant
  • 3-in-1 insulation, thermal break and vapour-permeable sarking
  • Helps achieve the home energy efficiency provisions
  • Quick and easy to install
  • Strong, tough, durable
  • Water-resistant and unaffected by moisture
  • Anti-bacterial and anti-fungal
  • Rodent and insect resistant
  • Compliant with AS/NZS 4859.1:2018
  • CodeMark-certified for NCC compliance

General install instructions

  1. Fit Kingspan AIR-CELL Permishield XV 70 neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage.
  2. When taping, a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping with Kingspan Aluminium Foil Tape.
  3. Leave minimum 100mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer).
These instructions are guidelines only and should be interpreted with consideration for the specific building design. The installation of Kingspan AIR-CELL should be in conformance with the applicable clauses from AS 3999:2015 and AS/NZS 4200.2:2017 unless otherwise specified. Kingspan AIR-CELL can be damaged by intense heat above 105°C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided. The installer must make due provision for safety when installing Kingspan AIR-CELL in any application.

Install instructions for timber-framed walls

  1. Roll out Kingspan AIR-CELL horizontally and fix to outside of frame.
  2. Cut Kingspan AIR-CELL carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL sheets and tape with a 48mm wide reinforced foil tape.
  4. Fix counter battens and exterior cladding.

Install instructions for steel-framed walls

  1. Fix Kingspan AIR-CELL loosely to the outside of frame leaving flexibility for Kingspan AIR-CELL to be dished onto the wall cavity.
  2. Cut Kingspan AIR-CELL carefully around doors, windows and other openings, so that it neatly abuts to frames.
  3. Butt join Kingspan AIR-CELL sheets and tape with a 48mm wide reinforced foil tape.
  4. Provide for outer air space by adhering the Kingspan AIR-CELL Spacer Biscuits to the outer face of the Kingspan AIR-CELL (approximately three (3) Spacer Biscuits per square metre required).
  5. Commence installing cladding in accordance with manufacturer's installation instructions.

1
Technical data
BrandKingspan
MaterialFoil / Reflective
Applicationwall
FireCombustible
Your job

Reverse brick veneer walls

Summarised from the Kingspan AIR-CELL Permishield XV 70 data sheet (KIAU0047, Issue 15, September 2023). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Fix to the battens
  • Roll out Kingspan AIR-CELL Permishield XV 70 horizontally and fix it to the battens.
2Cut around openings
  • Cut carefully around doors, windows and other openings so the insulation neatly abuts the frames.
3Butt join and tape
  • Butt join the sheets and tape them with 48mm wide reinforced foil tape.
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
4Fix battens and cladding
  • Fix the counter battens and the exterior cladding.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Steel-framed walls

Summarised from the Kingspan AIR-CELL Permishield XV 70 data sheet (KIAU0047, Issue 15, September 2023). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Fix loosely to the frame
  • Fix Kingspan AIR-CELL Permishield XV 70 loosely to the outside of the frame, leaving flexibility for it to be dished into the wall cavity.
2Cut around openings
  • Cut carefully around doors, windows and other openings so the insulation neatly abuts the frames.
3Butt join and tape
  • Butt join the sheets and tape them with 48mm wide reinforced foil tape.
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
4Add the Spacer Biscuits
  • Adhere Kingspan AIR-CELL Spacer Biscuits to the outer face of the insulation to create the outer air space.
  • Allow approximately three Spacer Biscuits per square metre.
5Install the cladding
  • Install the cladding in accordance with the cladding manufacturer's installation instructions.
6Take care with fibre-cement
  • Screw fibre-cement cladding through the insulation to the steel frame, with even pressure so the upper board overlap is in full contact with the lower board, and close any gaps with brad nails.
  • Set the screw gun torque and depth so the insulation gets even pressure without overstressing the cladding.
  • For fibre-cement cladding less than 12mm thick, the counter-batten method (timber-framed walls) is preferred.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Timber-framed walls (counter battens)

Summarised from the Kingspan AIR-CELL Permishield XV 70 data sheet (KIAU0047, Issue 15, September 2023). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Fix to the frame
  • Roll out Kingspan AIR-CELL Permishield XV 70 horizontally and fix it to the outside of the frame.
2Cut around openings
  • Cut carefully around doors, windows and other openings so the insulation neatly abuts the frames.
3Butt join and tape
  • Butt join the sheets and tape them with 48mm wide reinforced foil tape.
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
4Fix battens and cladding
  • Fix the counter battens and the exterior cladding.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
4.9 from 590 Trustpilot reviews

We collect verified reviews on Trustpilot across all our products and service.

Read all on Trustpilot →