Kingspan Kooltherm K17 Insulated PlasterboardR1.15 | 35.0 mm

Get 10% off as a trade customer. Open an instant trade account
Made to order. Allow 10 to 14 days for delivery.
Location Victoria
Thickness 35mm
Quantity calculator
34.6 m²
You need
packs
Actual area - m²
Total inc GST
-

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Australian-made
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639

Kingspan Kooltherm K17 - Insulated Plasterboard

Kingspan Kooltherm K17 Insulated Plasterboard is a fibre-free rigid thermoset, closed cell phenolic insulation, sandwiched between a front facing of tapered edge gypsum based plasterboard, and a reverse tissue based facing adhesively bonded to the insulation core during manufacture. Kingspan is renowned among plasterboard suppliers for it’s superbly insulated thermal plasterboard sheets. Alternative lining boards, such as fibre cement sheets, can also be bonded to the insulation core to create customised finishes and facings in our Kingspan Kooltherm K17 + Insulated Lining Board range.

K17 Plasterboard Features

  • Australian Made
  • CodeMark certified for NCC compliance
  • NCC and AS/NZS 4859.1:2018 compliant
  • Global GreenTag GreenRate-certified
  • Also used for residential & modular construction
  • Fire-free, closed cell insulation core
  • 3-in-1 insulation, dry lining and vapour control

Product Description and Durability

If correctly applied, Kingspan Kooltherm® products can be expected to have a long life of service. Their durability depends on the supporting structure and the conditions of its use. Kingspan Kooltherm® products are warranted for a period of 10 years for both residential and commercial installations. This is subject to the terms of the complete Kingspan Kooltherm® warranty document. Kingspan Kooltherm K17 Insulated Plasterboard has a gypsum plasterboard face. It should, therefore, not be used to isolate dampness nor be used in continuously damp or humid conditions. This product can be applied utilising a variety of traditional or modern dry-lining techniques, to dry and structurally sound walls. These include the construction adhesive bonding method. The particular system employed will depend on the construction or design of the wall to which Kingspan Kooltherm K17 Insulated Plasterboard is to be fixed. If an acceptable adhesive bond cannot be achieved due to the wall surface, consideration should be given to a mechanically fixed option. The tapered edge to the plasterboard enables a flat seamless surface equal to traditional plaster finishes after the correct jointing procedures as per plasterboard manufacturer’s recommendation have been completed.

Construction Adhesive Bonding

This method is for application to brick, block or concrete masonry cavity walls which are free from moisture penetration.
  1. Ensure that the wall surface to be bonded to is free from oil, grease, paint, release agent, or any contaminate that may affect the bond of the adhesive to the wall.
  2. Gun apply a continuous blob of construction adhesive around perimeter wall and ceiling junctions, and around any openings, such as windows and doors, in order to provide a seal.
  3. Gun apply blobs of construction adhesive to the wall or the back of the board approximately 25 mm in diameter (single squeeze), at 300 mm centres in both directions or to specific adhesive manufacturer’s instructions. Ensure that the blobs adjacent to a board joint are approximately 25 mm in from the edge to avoid bridging the joint.
  4. Tap the board back firmly using a straightedge, ensuring that the vertical edge is plumb.
  5. Continue dry lining in the same manner.
  6. Provide temporary mechanical support to the Kingspan Kooltherm K17 Insulated Plasterboard for at least 24 hours.
  7. Mechanical fixings are recommended to complement the adhesive bond. Apply 2 per board after the adhesive has set, positioned 15 mm in from the board edge and at mid height with a nominal 25 mm embedment into the wall. (Refer to fixing manufacturer instructions for more information).
  8. It is recommended that mechanical fixings are positioned in the tapered edge of the boards so that they are covered when the board is finished, (e.g. joints taped and skim coating) at mid height. Boards should be fitted tight to the ceiling/joists

Handling, Storage and Installation of Insulation Panels

The packaging of Kingspan Kooltherm® should not be considered adequate for long term outdoor protection. Ideally boards should be stored inside a building. If, however, outdoor storage cannot be avoided then the boards should be stacked clear of the ground and covered with an opaque polythene sheet or weatherproof tarpaulin. Boards that have been allowed to get wet should not be used. The insulation core is resistant to short–term contact with petrol and with most dilute acids, alkalis and mineral oils. However, it is recommended that any spills be cleaned off fully before the boards are installed. Ensure that safe methods of cleaning are used, as recommended by suppliers of the spilt liquid. The insulation core is not resistant to some solvent-based adhesive systems, particularly those containing methyl ethyl ketone. Adhesives containing such solvents should not be used in association with this product. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Kingspan panels are chemically inert and safe to use. Cutting should be carried out either by using a fine toothed saw, or by using a sharp knife to cut through the insulation and paper backing of the plasterboard, then snapping the board face down over a straight edge and cutting the paper facing of the plasterboard on the other side. Ensure accurate trimming to achieve close butting joints and continuity of insulation.
1
Technical data
BrandKingspan
MaterialPhenolic
Applicationwall
Sheet size2400 × 1200 mm
FireCombustible
Your job

Adhesive bonding to masonry

Summarised from the Kingspan Kooltherm K17 Insulated Plasterboard data sheet (Australia), Installation Instructions. Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Prepare the wall
  • Use this method on brick, block or concrete masonry cavity walls that are free from moisture penetration.
  • Make sure the wall is free from oil, grease, paint, release agent or anything else that may affect the adhesive bond.
2Seal the perimeter
  • Gun apply a continuous blob of construction adhesive around the wall and ceiling junctions and around openings such as windows and doors.
3Apply the adhesive blobs
  • Apply blobs of about 30 mm diameter at 300 mm centres in both directions, or to the adhesive manufacturer's instructions.
  • Keep blobs next to a board joint about 25 mm in from the edge so they do not bridge the joint.
4Tap the boards back
  • Tap each board back firmly with a straightedge, keeping the vertical edge plumb.
  • Fit the boards tight to the ceiling or joists and continue dry lining the same way.
5Add mechanical fixings
  • After the adhesive has set, apply six fixings per board, 15 mm in from the board edge at top and bottom, with a nominal 25 mm embedment into the wall.
  • Place the fixings in the tapered edge of the boards at mid height so they are covered when the board is finished.

Install in accordance with AS 3999:2015 Bulk thermal insulation, Installation.

Mechanical fixing to masonry

Summarised from the Kingspan Kooltherm K17 Insulated Plasterboard data sheet (Australia), Installation Instructions. Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Check the wall
  • Use this method on masonry walls free from moisture penetration where an adhesive bond is not suitable or heavy linings such as tiles will be applied.
  • Make sure the wall is true and free from projections that may stop the board sitting flat.
2Drill and anchor
  • Predrill into the wall with a masonry bit.
  • Insert a masonry anchor with a minimum 25 mm embedment into the structure.
3Space the fixings
  • Fix at 600 mm maximum horizontal centres and 300 mm maximum vertical centres, 15 mm in from the board edges.
4Drive fixings straight
  • Drive the fixings straight with the heads just below the plasterboard surface.
  • Take care not to overdrive the screws.

Install in accordance with AS 3999:2015 Bulk thermal insulation, Installation.

Metal or timber frames and battens

Summarised from the Kingspan Kooltherm K17 Insulated Plasterboard data sheet (Australia), Installation Instructions. Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Mark and fix the battens
  • Mark the walls at 600 mm maximum centres for the vertical battens and boards.
  • Fix battens or furrings vertically at 600 mm maximum centres, around the perimeter, windows, doors and any services that penetrate the system.
  • Pack battens out with proprietary shims where needed for alignment or services.
2Position the boards
  • Cut each board to allow a 5 to 10 mm height clearance.
  • Locate the board centrally over the framing and hold it firmly against it.
3Screw to every member
  • Fix to all framing members with drywall screws at 300 mm centres, reduced to 200 mm at external corners.
  • Choose screws that penetrate a nominal 10 mm into metal or 25 mm into timber studs.
4Finish the fixings
  • Drive screws straight with the heads just below the surface, without fracturing the plasterboard.
  • Lightly butt the boards and keep screws at least 10 mm from bound edges.

Install in accordance with AS 3999:2015 Bulk thermal insulation, Installation.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
ReturnsWithin 30 days
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
Is this right for your job?

Answer a few quick questions, or describe your job in your own words, and wAIse checks whether this R1.15 product fits and compares it with two alternatives.

Rather ask a person? Our team spec insulation all day. 1300 729 639 or send us your plans.