Kingspan Air-Cell Insulbreak 90 Insulation9.2 mm

Get 10% off as a trade customer. Open an instant trade account
Location Victoria
Dimensions 1350mm x 22.25m
Quantity calculator
30.0 m²
You need
rolls
Actual area - m²
Total inc GST
-

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Combined thermal break, vapour barrier and reflective insulation in one
  • Designed for roof and wall insulation
  • Covers 30 m² per pack
  • Needs an adjacent air gap to work, so it is not a stand-alone bulk insulator and gives less R than batts.
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639
Complete your order

Kingspan AIR-CELL Insulbreak 90 is a 9.2 mm reflective insulation that combines insulation, thermal break and vapour barrier. It has a cross-linked, closed-cell polyethylene foam core with an anti-glare foil face on one side and a plain foil face on the other. In steel-framed buildings it delivers the R0.20 thermal break required for NCC compliance, reducing thermal bridging between building elements. It is made in Australia by Kingspan Insulation.

Where to use it

  • Steel-framed walls on low rise structures: fixed loosely to the outside of the frame behind the cladding, with Kingspan AIR-CELL Spacer Biscuits on the outer face to create an air space. For high-rise buildings, Kingspan asks you to contact its Technical Services team.
  • Metal roofs: laid from ridge to gutter over and across the roof battens with a nominal 40 mm sag between battens, or rolled out across the rafters under the battens.
  • Timber framed roofs: Kingspan notes it is also commonly used in non-steel framed applications such as timber framed roofs.

Thermal performance

The material R-value is R0.25 m².K/W at 23°C (ASTM C518-2017). The total R-value in a building depends on installation and environmental conditions, so Kingspan publishes Total R-values for the building element as required by the NCC Energy Provisions, calculated to AS/NZS 4859.2:2018 and NZS 4214:2006:

  • Steel-framed wall: RT 1.4 heat flow in (summer), RT 1.4 heat flow out (winter)

Kingspan's data sheet gives a total R-value for Insulbreak 90 in a steel-framed wall only; it lists no roof figure for the 90.

The R-value is reduced if dust builds up on upward facing surfaces or the cavities are ventilated. Each foil face must sit next to an unventilated air space, which is also why doubling up layers does not improve performance.

Size

Rolls of 1350 mm x 22.25 m (30 m²). Nominal roll weight 10 kg and diameter 500 mm. Maximum span 2.4 m without support mesh.

What to check before you buy

  • Plan the air spaces: about three Spacer Biscuits per square metre in walls, and the sag between battens in roofs.
  • Kingspan does not recommend fixing external cladding thinner than 12 mm directly against AIR-CELL, to prevent a pillowing effect where the cladding warps around the fixings.
  • It is a Class 2 vapour barrier. Kingspan advises considering the NCC condensation management provisions for your climate zone when choosing a sarking-type material.
  • Foil facings conduct electricity, so avoid contact with un-insulated cables and fittings, and leave at least 100 mm clearance around hot flues and light fittings.

Good to know

  • CodeMark-certified for NCC compliance and compliant with AS/NZS 4859.1:2018.
  • Flammability index ≤ 5 (low) to AS 1530.2:1993. Kingspan states AIR-CELL is suitable for buildings in Bushfire Attack Levels 12.5 to 40.
  • Fibre-free, non-allergenic and non-irritant. Water-resistant, anti-bacterial and anti-fungal, and rodent and insect resistant.
  • Heat above 105°C damages it: keep sparks and flame from blow torches, welders and cutting tools away.
  • Transport and store rolls in their packaging, clean and dry, standing on end, and away from wet cement or lime.
  • Kingspan's AIR-CELL warranty covers manufacturing defects for 15 years from installation, provided it is installed by a qualified tradesman to Kingspan's instructions.

The Installation tab has the full steps for metal roofs and steel-framed walls.

1
Technical data
BrandKingspan
MaterialFoil / Reflective
Applicationroof, wall
FireCombustible
Material R-valueR0.25 m².K/W at 23°C (ASTM C518-2017)
Vapour permeance classClass 2 vapour barrier (ASTM E96 Part B:2016)
Water barrierWater barrier (AS/NZS 4201.4:1994)
Flammability indexLow, ≤ 5 (AS 1530.2:1993)
Bushfire useBAL-12.5 to BAL-40 (Kingspan)
Weight10 kg per roll (nominal)
Total R-values (Kingspan AIR-CELL Insulbreak 90)
ConstructionHeat flow in (summer)Heat flow out (winter)
Steel-framed wallRT 1.4RT 1.4

Total R-values for the building element as required by the NCC Energy Provisions, calculated to AS/NZS 4859.2:2018 and NZS 4214:2006 for the steel-framed wall in Kingspan's data sheet, with Spacer Biscuits creating the air space behind the cladding.

Your job

Metal roofs, over the battens

Summarised from the Kingspan AIR-CELL Insulbreak data sheet (KIAU0040, Issue 19, February 2025). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Lay over the battens
  • Lay Kingspan AIR-CELL Insulbreak from the ridge to the gutter, over and perpendicular to the roof battens.
2Set the overlap and sag
  • Allow a maximum 25 mm overlap into the gutter.
  • Allow a nominal 40 mm sag between battens.
3Overlap the joins
  • Overlap joins by 150 mm, or by 50 mm where the joins are taped.
  • Overlap end joins by 600 mm if they are not taped.
4Tape with a squeegee
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
5Hold it until roofing
  • Staple or tape the insulation to the battens to hold it in place until the roofing is fixed.
6Seal and clear services
  • Fit the insulation neatly around doors, windows and penetrations, and tape where needed to prevent air leakage.
  • Leave at least 100 mm clearance around heat producing flues and light fittings.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Metal roofs, under the battens

Summarised from the Kingspan AIR-CELL Insulbreak data sheet (KIAU0040, Issue 19, February 2025). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Start at the gutter
  • Roll out Kingspan AIR-CELL Insulbreak across the rafters with the anti-glare side up.
  • Allow a maximum 25 mm overlap into the gutter.
2Fix to the rafters
  • Fix the insulation to the rafters.
3Overlap the joins
  • Overlap joins by at least 150 mm, or by 50 mm where the joins are taped.
  • Overlap end joins by the rafter spacing if they are not taped.
4Tape with a squeegee
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
5Fix the battens
  • Fix the battens to suit the roof covering requirements and applicable standards.
6Seal and clear services
  • Fit the insulation neatly around doors, windows and penetrations, and tape where needed to prevent air leakage.
  • Leave at least 100 mm clearance around heat producing flues and light fittings.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Steel-framed walls

Summarised from the Kingspan AIR-CELL Insulbreak data sheet (KIAU0040, Issue 19, February 2025). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Fix loosely to the frame
  • Fix Kingspan AIR-CELL Insulbreak loosely to the outside of the frame, leaving flexibility for it to be dished into the wall cavity.
  • It suits metal framed walls on low rise structures; for high-rise buildings, contact Kingspan Insulation's Technical Services Team.
2Cut around openings
  • Cut carefully around doors, windows and other openings so the insulation neatly abuts the frames.
3Butt join and tape
  • Butt join the sheets and tape them with 48 mm wide reinforced foil tape.
  • Press the tape down with a plastic squeegee or blade, on surfaces that are dry and free from dust, oil or grease.
4Add the Spacer Biscuits
  • Adhere Kingspan AIR-CELL Spacer Biscuits to the outer face of the insulation to create the outer air space.
  • Allow approximately three Spacer Biscuits per square metre.
5Install the cladding
  • Install the cladding in accordance with the cladding manufacturer's installation instructions.
6Seal and clear services
  • Fit the insulation neatly around doors, windows and penetrations, and tape where needed to prevent air leakage.
  • Leave at least 100 mm clearance around heat producing flues and light fittings.

Install in conformance with the applicable clauses of AS 3999:2015 and AS/NZS 4200.2:2017. Foil facings conduct electricity, so avoid contact with un-insulated electrical cables and fittings.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
ReturnsWithin 30 days
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
4.9 from 590 Trustpilot reviews

We collect verified reviews on Trustpilot across all our products and service.

Read all on Trustpilot →