Foilboard Flexifast Fasteners

Get 15% off as a trade customer. Open an instant trade account
Location Victoria
Pack Size 400 pcs
$91.91
per pack inc GST

We do not hold stock for your state. Tell us what you need and we will quote you on product and delivery.

4.9 from 590 Trustpilot reviews Delivery in 1 to 2 business days Secure checkout
  • Purpose-made fixings for a secure, correct installation
  • Matched accessory for a complete, airtight install
Rather not install it yourself? See our installation service.
Prefer to order by phone? Call 1300 729 639

Foilboard Flexifast Fasteners

Flexifast Fastener is not only fast and extremely flexible in its use, but also adjustable, making it the perfect solution for many applications. Foilboard Flexifast can be used to insulate existing structures or new projects. Foilboard® Flexifast allows all Foilboard® products to be installed in underfloors, walls and ceilings. Simply cut Foilboard to desired size, insert Flexifast into the Foilboard®. Gently push between framework and fix. Flexifast should be installed at 600mm centres. All joins should be taped for maximum performance.

Suitable for all applications

Foilboard Australia Pty Ltd manufactures a range of fixing accessories tailored to suit many construction applications. These Foilboard timber fasteners ensure that the material will be installed correctly and maintain its thermal performance for the life of the application. Whether it is for timber or steel frame construction, underfloor applications and even commercial systems, Foilboard® has the right fixings to suit all applications.

Foilboard Flexifast Fastener Installation Instructions

1. Push the Foilboard Flexifast ® fastener into the desired position in your Foilboard® sheet, using the specially designed prongs, and then position the board where it is required. 2. Fasten the Flexifast® fastener with either nails or screws where appropriate. 3. Foilboard® recommends the use of 1 Flexifast® fastener every 600mm for maximum stability. 4. To finish the perfect installation of Foilboard®, all sheets must be taped where they join to prevent air infiltration, therefore maintaining your desired R-Value. Instructions are a guideline only and should be interpreted with consideration for the specific building application. Safe installation practices are encouraged at all times.

Method of Calculating Quantities of Foilboard

  • Measure Floor or Wall area.
  • Add 5% to area to allow for cutting and waste, deduct window and door openings.
  • If using 2.44m sheets divide the area by 2.93 to give the number of sheets required.
  • If using 2.70m sheets divide the area by 3.24 to give the number of sheets required.
  • Round up to the next full sheet.
  • Floor saddles should be on joists at approx 600mm centres and spaced at 200mm from sheet ends.
  • For retro-fits Foilboard should span across the underside of joists and between bearers using three Foilboard fasteners per joist. Joins do not need to be made on a joist and you should tape all joins.
  • Generally 1 bag of saddles is required for every 45-50m2 and 1 Role of Green Tape will be required for every 100m2. For retro-fits you will generally require 1 bag of Foilboard Fasteners and 1 roll of Green Tape for every 15-20 sheets, for Aluminium tape you will require one roll for every 10-12  sheets approx. Flexifastners should be used for all sheets 25mm or thicker and you will require 1 bag of 200 fastners for every 15-20 sheets. Or for sheets over 25mm in thickness you can order the plastic plates and supply your own fixing nails or screws. Spacers for brick work you will require 8-10 spacers per m2

Residential Wall

For example, an area of 130m2 (residential wall – timber/steel frame excluding windows) will require;
  • 45 sheets of Foilboard® Insulation Panel (2440mm x 1200mm, 2.93m2 per sheet)
  • 3 bags of fasteners (Standard or Ultra or Flexifast)
  • 3 Rolls of Green UV PVC Tape

Underfloor Area

For traditional underfloor applications using timber joists at 450mm centres (130m2);
  • 45 sheets of Foilboard® Insulation Panel (2440mm x 1200mm, 2.93m2 per sheet)
  • 3 bags of Foilboard® Floor Saddles or Flexifast Fasteners
  • 3 Rolls of Green UV PVC Tape
1
Technical data
BrandFoilboard
MaterialFoil / Reflective
Your job

Underfloor with Flexifast fasteners

Summarised from the Foilboard Installation Guide, Underfloor, Flexifit (V0126, January 2026). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Measure between the joists
  • Measure the required area between the joists and mark the panel.
  • Add 2 mm to each measurement for a snug fit, and cut across the panel width so each piece is 1200 mm long.
2Cut the panel
  • Cut the panel to size with a straight edge and a sharp knife.
3Attach Flexifast fasteners
  • Attach Foilboard Flexifast fasteners to the edges of the panel, 300 mm from the end and at 600 mm intervals.
4Fix between the joists
  • Position the panel between the joists and fix it in place with the Flexifast fasteners.
  • The anti-glare side typically faces up in this application.
5Tape and seal
  • Tape any joins, exposed edges or gaps with Foilboard joining tape, so the reflective air space is enclosed.
  • Seal minor gaps with a high temperature, neutral cure silicone.

Foilboard panels contain aluminium foil, which conducts electricity, so keep them clear of electrical wiring and refer to AS 3999 or a licensed electrician. Replace, paint or cover any skylight or glass above or beside the panels before installing.

Cathedral or skillion roofs

Summarised from the Foilboard Installation Guide, Roof, Cathedral or Skillion, Retrofit (V0126, January 2026). Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Measure between the rafters
  • Measure the required area, then mark the Foilboard panel before cutting.
  • Add 2 mm to each measurement for a snug fit that allows for slight variation between the rafters.
2Cut the panel
  • Cut the panel to size with a straight edge and a sharp knife.
3Attach Flexifast fasteners
  • Attach Foilboard Flexifast fasteners to the edges of the panel, 300 mm from the end and at 600 mm intervals.
4Fix between the rafters
  • Position the panel between the rafters and fix it with the Flexifast fasteners.
5Tape and finish
  • Tape any joins, exposed edges or gaps with Foilboard joining tape, and seal minor gaps with a high temperature, neutral cure silicone.
  • Plaster to finish.

Foilboard panels contain aluminium foil, which conducts electricity, so keep them clear of electrical wiring and refer to AS 3999 or a licensed electrician. Replace, paint or cover any skylight or glass above or beside the panels before installing.

Large shed roof, between purlins

Summarised from the Foilboard Installation Guide, Shed, Large Structure (V0126, January 2026), page 1. Work from the full guide: it has the drawings and every detail. Open the full guide (PDF)

1Measure between the purlins
  • Measure the space between the purlins or top hats and cut the panel to size with a straight edge and a sharp knife.
2Attach Flexifast fasteners
  • Push the Flexifast fastener spikes into the sides of the panel, starting 300 mm from the end and spaced 600 mm apart.
3Fit and screw
  • Fit the panels between the purlins and secure them by screwing through the Flexifast fasteners.
4Tape the joins
  • Tape any joins, exposed edges or gaps with Foilboard joining tape.
  • In commercial sheds the ceiling lining is usually fixed directly to the purlins or top hats, over the Foilboard.

Foilboard panels contain aluminium foil, which conducts electricity, so keep them clear of electrical wiring and refer to AS 3999 or a licensed electrician. Replace, paint or cover any skylight or glass above or beside the panels before installing.

Delivery & pickup
Delivery1 to 2 business days
Delivery costFrom $99 metro, priced by postcode
Delivery dateChoose yours in the cart
Warehouse pickupVIC, NSW, QLD, SA and ACT
ReturnsWithin 30 days
Need it today?Ask us about same day delivery on 1300 729 639

We deliver to homes and building sites right across Australia. Choose your preferred delivery date at the online checkout and we'll confirm the same business day.

Full delivery & pickup info →
4.9 from 590 Trustpilot reviews

We collect verified reviews on Trustpilot across all our products and service.

Read all on Trustpilot →